Water Chiller: Difference between revisions
From CoMakingSpace Wiki
(Created page with "{{MachineInfoBox |machine name=CW4000 |image= |synonyms=DE: Wasserkühlung |type=laser cutter periphery |material= |location=Location::Electronics Room|eRoo...") |
(error messages) |
||
Line 29: | Line 29: | ||
* refrigerant: R134a | * refrigerant: R134a | ||
* tubing: Rp 1/2 (DN15) | * tubing: Rp 1/2 (DN15) | ||
== Error Messages == | |||
* E02: temperature error | |||
** room/water below 5 or above 25°C? | |||
* E05: flow restriction | |||
** bends in the tubing? | |||
** water level too low? |
Revision as of 22:11, 12 March 2020
MachineInfoBox CW4000 | |
---|---|
Synonyms: | DE: Wasserkühlung |
Access Requirements: | Laser Cutter Introduction, Lasercutter-Einweisung<ul><li>The part "|laser cutter" of the query was not understood.Results might not be as expected.</li> <!--br--><li>The part "periphery" of the query was not understood.Results might not be as expected.</li> <!--br--><li>The part "]]" of the query was not understood.Results might not be as expected.</li></ul> |
Tutors: | NitramLegov Pakue Lmnl99 Johannes Luzian Keno Utis Sebastian Kalunho Björn, NitramLegov Pakue Lmnl99 Johannes Luzian Keno Utis Sebastian Kalunho Björn<ul><li>The part "|laser cutter" of the query was not understood.Results might not be as expected.</li> <!--br--><li>The part "periphery" of the query was not understood.Results might not be as expected.</li> <!--br--><li>The part "]]" of the query was not understood.Results might not be as expected.</li></ul> |
[[Has caption::laser cutter periphery| ]]
We have a "CW4000" water chiller that is dedicated to the laser cutter.
Never fire up the laser without proper cooling!
Filling
The unit is filled from the top where you can remove the clear plastic lid. If the temperature may drop below 5°C the laser cutter's manual advises the use of company-approved antifreeze (NOT the stuff for cars, apparently it can break the tubing and seals!). Pending first experiences, we may also need to think about an additional sterilizing agent in case algae or fungi start feeling at home in the water...
1st fill: just distilled water, 2020-3-12
Specs
From the HPC product page:
- tank volume: 3.2 L
- refrigerant: R134a
- tubing: Rp 1/2 (DN15)
Error Messages
- E02: temperature error
- room/water below 5 or above 25°C?
- E05: flow restriction
- bends in the tubing?
- water level too low?