Water Chiller: Difference between revisions

From CoMakingSpace Wiki

(Created page with "{{MachineInfoBox |machine name=CW4000 |image= |synonyms=DE: Wasserkühlung |type=laser cutter periphery |material= |location=Location::Electronics Room|eRoo...")
 
m (Outsourcing)
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{MachineInfoBox
<br clear="all" />
|machine name=CW4000
<!--  NOTE: The following block "imports" content from separate pages - please don't change the code! To edit the actual information, please go back and click "edit" next to the section headline you are interested in :-)  -->
|image=
{{#ask:
|synonyms=DE: Wasserkühlung
[[MachineType::{{PAGENAME}}]]
|type=[[Laser Cutter|laser cutter]] periphery
|order=ascending
|material=
|format=embedded
|location=[[Location::Electronics Room|eRoom]]
|embedonly=yes
|access=
|status=
|firmware=
|software=
|manual=
|tutors=
|used with=
|similar=
}}
}}
We have a "CW4000" water chiller that is dedicated to the [[Laser Cutter|laser cutter]].
[[Category:Laser Cutting]]
 
'''Never fire up the laser without proper cooling!'''
 
== Filling ==
The unit is filled from the top where you can remove the clear plastic lid. If the temperature may drop below 5°C the laser cutter's manual advises the use of company-approved antifreeze (NOT the stuff for cars, apparently it can break the tubing and seals!). Pending first experiences, we may also need to think about an additional sterilizing agent in case algae or fungi start feeling at home in the water...
 
1st fill: just distilled water, 2020-3-12
 
== Specs ==
From the [https://hpclaser.co.uk/p/cw4000-water-chiller-unit/ HPC product page]:
* tank volume: 3.2 L
* refrigerant: R134a
* tubing: Rp 1/2 (DN15)

Latest revision as of 20:58, 24 October 2022


CW4000

MachineInfoBox

CW4000

Water chiller CW4000.JPG
Synonyms: DE: Wasserkühlung
Type: Water Chiller
Used with: Laser Cutter
Location: Laser Area
Access Requirements:
Status: Working
Tutors:



We have a "CW4000" water chiller that is dedicated to the laser cutter.

Never fire up the laser without proper cooling! In fact, it will not even let you activate the CO2 tube if the water is flowing in the wrong direction ("outlet" of the chiller has to go into "inlet" of the laser cutter and vice versa).

Filling

The unit is filled from the top where you can remove the clear plastic lid. If the temperature may drop below 5°C the laser cutter's manual advises the use of HPC-approved antifreeze (NOT the stuff for cars, apparently it can break the tubing and seals!). This solution from BDI Cooling might also be worth a look because it sounds like it might be the same thing (ethylene glycol plus "DeTox").

The antifreeze would also be useful due to its additional sterilizing agents: in regular distilled water, we are seeing lots of algae/fungi growth and have to replace it every few weeks...there are even stories online where the gunk caused serious blockage in the glass tubes that are difficult to clean!

1st fill: just distilled water, 2020-3-12 (did not keep track after that)

Specs

  • target temperature: 18 °C

From the HPC product page:

  • tank volume: 3.2 L
  • refrigerant: R134a
  • tubing: Rp 1/2 (DN15)

Error Messages

  • E02: temperature error
    • room/water below 5 or above 25°C?
  • E05: flow restriction
    • bends in the tubing?
    • water level too low?